1, common is the resonant capacitor C6
breakdown (short circuit) or pressure reduction (soft breakdown), should be
replaced by the high-quality polyester or CBB capacitor that the same voltage capacity is above 1kV .
2, open filament lamp. If the lamp is not
serious black, parallel 0.047μF/400V across broken wire foot after
emergency use polyester capacitors.
3, R1, R2 open or variable value
(generally greater possibility is failure in R1),substitution with the same high-resistance
resistor 1/4W .
4, transistor open. Found that
only one transistor open, but can not replace one, should replace one pair
of voltage above 400V same model in pairing switch. Or prone to rolling or
re-burn tube lights.
5, lights flashing. If lamp is serious black, check D5, D6 whether the Weld or open, if D5, D6 soft breakdown or
filter capacitor C1 leakage and adverse, which also make lights flash.
6,it is difficult to light up the lamp ,
sometimes touching the lamp can be lit or lights roll, which may be C3, C4
insufficient capacity mismatch.
7, if the single low-power
energy-saving lamps lit filament emerging redness or luminous phenomena should
also check whether the soft breakdown D1 ~ D4, C1 is installed backwards or
leakage, power supply part is short
circuit or not.
8, Chokes L, and the oscillation
transformer B, cores are broken. Should single core change, we should pay
attention to three points: (1) using the core to meet the requirements,
otherwise it may cause choke inductance values have
greater access to lay hidden energy-saving lamps; (2) the magnetic gap is not
too small, so magnetic saturation; (3) after interstitial magnetic material
with a suitable pad,a good pad with adhesive glue and wrap high temperature flame
retardant tape, to prevent loosening. In addition can not pick the wrong side to
B with the same name.
9, repair using trigger tube electronic
ballast, should focus on checking bidirectional trigger diode, this pipe is
generally used DB3 type, it's two-way breakdown voltage is 32 ± 4V.